FLir indentiFINDER R440

The FLIR identiFINDER R440 is a lightweight, sourceless radionuclide identification device (RID) that can be operated with one hand and is IP67-rated to survive tough missions. Not only does the 2×2 NaI detector deliver sensitive and fast detection, but it also provides accurate identification during secondary screening. The new 360° EasyFinder™ Mode expedites decision-making to keep you safe.

HIGHLY SENSITIVE 2X2 NAI DETECTOR

Detects radiological threats from farther away, behind heavier shielding, and with better resolution than similarly sized RIDs.

RUGGED CONSTRUCTION

Drop-tested to 1m, completely enclosed crystal, and IP67-rated enclosure that protects against dust and water immersion up to 1m.

STATE-OF-THE-ART USER FEATURES

360° EasyFinder Mode pinpoints and instructs operator on exact location of radiation source to keep responders and the community safe.

SPECIFICATIONS

SYSTEM OVERVIEW

Enclosure & Protection
Aluminum housing; protection rating IP67 according to IEC 60529
Technology
Radioisotope identification device (RIID)
Threats
Detects neutron or gamma radiation emitted from natural occurrences in the environment, special nuclear material, industrial, or medical material

ENVIRONMENTAL

Operating Humidity
10 to 93%
Storage Temperature
14 to 95 °F (-10 to 35 °C)

PHYSICAL FEATURES

Dimensions (L x W x H)
≤ 4 x 10.6 x 3.7 in (10.2 x 26.9 x 9.4 cm) – with battery
Weight
≤3.2 lbs (≤1.5 kg)

POWER

Battery Specs
Supplied: 2x rechargeable Li-Ion smartpacks and 1x 4x AA pack; ≤6h runtime with one Li-Ion smartpack, ≤12h with both Li-Ion; runtime of ≤4h with AA battery pack (Li-ion);Optional rechargable NiMH ion smartpack with ≤5h runtime; recharge ≤4h when using AC; recharge >4h when using USB; run times specified are obtained with a mix of Dose Rate, Finder, and ID operating mode
Cold Start Time
<2 mins from cold start
Input Voltage
100-240V AC (wall adapter and USB cable supplied)

SAMPLING & ANALYSIS

Library Categories
SNM, IND, MED, NORM
Nuclide Identification
According to ANSI N42.34
Sample Introduction
Absorption of EM gamma (NaI) or gamma and neutron emissions (NaIL)
Time to Alarm
From a few seconds to minutes

SYSTEM INTERFACE

Communication
USB 2.0, USB OTG; Bluetooth® Class 2.0 ≤10m range (removable); WiFi 802.11 g/n
Data Storage
32GB internal memory
Software
On-board webserver software
Training Requirements
<10 mins for operator; 1 day for advanced user

TECHNOLOGY

Energy Range [Gamma]
10 keV to 10 MeV
Linearization
Real-time linearization of gamma energy
Service Interval
1 year factory maintenance suggested, not required
Stabilization
Sourceless gain stabilization (patents pending)
Typical Resolution
≤7% FWHM at 662 keV with NaI detector at 20 °C